<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>S.A.F.E. Firefighter &#187; forcible entry</title>
	<atom:link href="http://safefirefighter.com/tag/forcible-entry/feed/" rel="self" type="application/rss+xml" />
	<link>http://safefirefighter.com</link>
	<description>Safe, Aggressive, Fundamentally-sound &#38; Efficient</description>
	<lastBuildDate>Fri, 03 Sep 2010 02:53:22 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.0.1</generator>
		<item>
		<title>Commercial Forcible Entry for Residential Doors</title>
		<link>http://safefirefighter.com/2010/05/26/through-the-lock-faster-than-the-irons/</link>
		<comments>http://safefirefighter.com/2010/05/26/through-the-lock-faster-than-the-irons/#comments</comments>
		<pubDate>Wed, 26 May 2010 14:18:14 +0000</pubDate>
		<dc:creator>safefirefighter</dc:creator>
				<category><![CDATA[Fire Rescue Topics]]></category>
		<category><![CDATA[Firefighting Operations]]></category>
		<category><![CDATA[Strategy and Tactics]]></category>
		<category><![CDATA[Training & Development]]></category>
		<category><![CDATA[Truck Work]]></category>
		<category><![CDATA[Videos]]></category>
		<category><![CDATA[doors]]></category>
		<category><![CDATA[fire]]></category>
		<category><![CDATA[forcible entry]]></category>
		<category><![CDATA[locks]]></category>
		<category><![CDATA[safety]]></category>
		<category><![CDATA[strategy]]></category>
		<category><![CDATA[tactics]]></category>

		<guid isPermaLink="false">http://safefirefighter.com/?p=261</guid>
		<description><![CDATA[This door is pretty intense and, if not identified recognized on scene, could waste time and energy should we have to gain entry i[...]]]></description>
			<content:encoded><![CDATA[<div class="tweetmeme_button" style="float: right; margin-left: 10px;">
			<a href="http://api.tweetmeme.com/share?url=http%3A%2F%2Fsafefirefighter.com%2F2010%2F05%2F26%2Fthrough-the-lock-faster-than-the-irons%2F"><br />
				<img src="http://api.tweetmeme.com/imagebutton.gif?url=http%3A%2F%2Fsafefirefighter.com%2F2010%2F05%2F26%2Fthrough-the-lock-faster-than-the-irons%2F&amp;style=normal" height="61" width="50" /><br />
			</a>
		</div>

<a href='http://safefirefighter.com/2010/05/26/through-the-lock-faster-than-the-irons/new-door/' title='New Door'><img width="150" height="150" src="http://safefirefighter.com/files/2010/05/New-Door-150x150.jpg" class="attachment-thumbnail" alt="New Door" title="New Door" /></a>
<a href='http://safefirefighter.com/2010/05/26/through-the-lock-faster-than-the-irons/new-security-door/' title='New Security Door'><img width="144" height="119" src="http://safefirefighter.com/files/2010/05/New-Security-Door.jpeg" class="attachment-thumbnail" alt="New Security Door" title="New Security Door" /></a>

<p>I caught this on <a title="VES" href="http://vententersearch.com" target="_blank">vententersearch.com</a> the other day and then was forwarded a link to additional info by LT Derek Franks (BTFD T375).  This door is pretty intense and, if not identified recognized on scene, could <strong>waste time and energy</strong> should we have to gain entry into a building.</p>
<p>Essentially, they are <strong>high security, reinforced steel doors with up to six (6) dead bolts (controlled by a single lock) and dressed to look like standard residential wooden doors</strong>.  Though it&#8217;s deceiving, <strong>shocking the door</strong> prior to attempting to force it should help you identify its construction as well as strong, and not-as-strong, points.</p>
<p>After seeing pictures and watching the video, it seems that either a K12 or solid <strong>through-the-lock techniques </strong>may be the best option if you find yourself up against this door.  Since all of the throws are controlled by one lock, pulling or spinning the lock and using key tools should be pretty quick.</p>
<p>Here are some links to info about the doors and to some tactics for forcible entry:</p>
<p><a href="http://www.vententersearch.com/?p=837"> Residential Security Door </a> &#8211; from vententersearch.com</p>
<p><a title="Master Security Doors" href="http://mastersecuritydoors.com" target="_blank">Master Security Doors</a> &#8211; Manufacturer&#8217;s website</p>
<p><a title="DIY Deconstruction Master Security Doors" href="http://www.youtube.com/watch?v=puscHttT2ss&amp;feature=related" target="_blank">How It&#8217;s Made</a> &#8211; Master Security Door YouTube Video</p>
<p><a title="Shocking the Door" href="http://www.youtube.com/watch?v=l_g-A4RDRS4" target="_blank">Shocking Doors</a> &#8211; YouTube video from Brotherhood Instructors</p>
<p><a title="Through-the-Lock" href="http://www.youtube.com/watch?v=WeXxb3-Mc38" target="_blank">Through-the-Lock</a> &#8211; YouTube video from Bellingham Fire Department</p>
]]></content:encoded>
			<wfw:commentRss>http://safefirefighter.com/2010/05/26/through-the-lock-faster-than-the-irons/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Lessons Learned: Solid Truck Work Makes for Easy Engine Work</title>
		<link>http://safefirefighter.com/2009/10/26/solid-truck-work-makes-for-easy-engine-work/</link>
		<comments>http://safefirefighter.com/2009/10/26/solid-truck-work-makes-for-easy-engine-work/#comments</comments>
		<pubDate>Tue, 27 Oct 2009 00:30:58 +0000</pubDate>
		<dc:creator>safefirefighter</dc:creator>
				<category><![CDATA[Firefighting Operations]]></category>
		<category><![CDATA[Fires]]></category>
		<category><![CDATA[Lessons Learned]]></category>
		<category><![CDATA[Strategy and Tactics]]></category>
		<category><![CDATA[Training & Development]]></category>
		<category><![CDATA[Truck Work]]></category>
		<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[Engine]]></category>
		<category><![CDATA[forcible entry]]></category>
		<category><![CDATA[saw]]></category>
		<category><![CDATA[strategy]]></category>
		<category><![CDATA[tactics]]></category>
		<category><![CDATA[truck]]></category>

		<guid isPermaLink="false">http://safefirefighter.com/?p=111</guid>
		<description><![CDATA[Aggressive tactics and a coordinated effort make a quick stop of a large and challenging fire in a commercial storage building.  S[...]]]></description>
			<content:encoded><![CDATA[<div class="tweetmeme_button" style="float: right; margin-left: 10px;">
			<a href="http://api.tweetmeme.com/share?url=http%3A%2F%2Fsafefirefighter.com%2F2009%2F10%2F26%2Fsolid-truck-work-makes-for-easy-engine-work%2F"><br />
				<img src="http://api.tweetmeme.com/imagebutton.gif?url=http%3A%2F%2Fsafefirefighter.com%2F2009%2F10%2F26%2Fsolid-truck-work-makes-for-easy-engine-work%2F&amp;style=normal" height="61" width="50" /><br />
			</a>
		</div>
<p><em>The following is an article contributed by Chris Garniewicz, a Truck Captain for the Bluffton Township Fire District.  He was the first due truck officer at the following incident and these are his accounts and lessons learned from that fire:</em></p>
<p>On September 11<sup>th</sup>, 2009 at 2107 hours, Bluffton Fire responded to a reported (building) fire at 154 Bluffton Road.  While companies were enroute, Dispatch advised there were multiple calls for the fire.  The first due company was delayed, so the truck and the second due engine arrived first together with the Battalion Chief.  A thermal column was seen on approach, and on arrival there was<strong> heavy smoke pushing from the eaves and doors of a 5000 square foot, 13-unit storage facility</strong>.  <strong>Apparatus positioning was a challeng</strong><strong>e</strong>, due to very narrow and obstructed driveways, requiring the engine to position on the Alpha side for fire attack while the truck positioned on the Charlie/Delta corner and split crews, establishing two forcible entry teams.</p>
<p>The building was <strong>type 2B construction</strong>, with no fire stops between units (overhaul revealed an approximately 6” gap at ceiling level, allowing fire and heat to spread between all units).  Due to the mixture of combustibles within the units, the smoke was thick and dark.  First arriving companies identified the unit of origin by the <strong>warping and discoloration of the steel doors and metal siding</strong>.</p>
<p>The decision was made by the engine officer to aggressively attack the unit of origin, then the units on all sides working out from the fire.  Truck crews were assigned to open all the doors to facilitate attack and overhaul.<em> </em>During forcible entry operations, truck members were met with a few challenging lock configurations and locations.  The number of locks and lock types created a time issue.  As a result, <strong>crews decided to cut the door instead of wasting time with removing multiple locks</strong>.</p>
<p>In order to access the fire units and exposure units quickly, the truck crew <strong>initially made “A” cuts</strong> to allow for knockdown, then came back during overhaul and made <strong>full height and width horizontal cuts to allow safer operations</strong> within the units.  The initial cut into the fire units allowed the engine crew to stop the fire spread rapidly and minimize damage to the other units. In all, 13 overhead doors were cut and/or forced and the fire was extinguished with two handlines. The <strong>aggressive tactics</strong> and <strong>coordinated efforts</strong> of the companies allowed for a large
<a href='http://safefirefighter.com/2009/10/26/solid-truck-work-makes-for-easy-engine-work/img_2107/' title='Horizontal Cut'><img width="150" height="150" src="http://safefirefighter.com/files/2009/09/IMG_2107-150x150.jpg" class="attachment-thumbnail" alt="Horizontal Cut" title="Horizontal Cut" /></a>
<a href='http://safefirefighter.com/2009/10/26/solid-truck-work-makes-for-easy-engine-work/img_2102/' title='Delta Side (Unit of Origin)'><img width="150" height="150" src="http://safefirefighter.com/files/2009/09/IMG_2102-150x150.jpg" class="attachment-thumbnail" alt="Delta Side (Unit of Origin)" title="Delta Side (Unit of Origin)" /></a>
<a href='http://safefirefighter.com/2009/10/26/solid-truck-work-makes-for-easy-engine-work/img_2106/' title='Unit of Origin'><img width="150" height="150" src="http://safefirefighter.com/files/2009/09/IMG_2106-150x150.jpg" class="attachment-thumbnail" alt="Unit of Origin" title="Unit of Origin" /></a>
<a href='http://safefirefighter.com/2009/10/26/solid-truck-work-makes-for-easy-engine-work/img_2108/' title='Leftovers of an &quot;A&quot; cut'><img width="150" height="150" src="http://safefirefighter.com/files/2009/09/IMG_2108-150x150.jpg" class="attachment-thumbnail" alt="Leftovers of an &quot;A&quot; cut" title="Leftovers of an &quot;A&quot; cut" /></a>
<a href='http://safefirefighter.com/2009/10/26/solid-truck-work-makes-for-easy-engine-work/img_2113/' title='Triple Locks'><img width="150" height="150" src="http://safefirefighter.com/files/2009/09/IMG_2113-150x150.jpg" class="attachment-thumbnail" alt="Triple Locks" title="Triple Locks" /></a>
<a href='http://safefirefighter.com/2009/10/26/solid-truck-work-makes-for-easy-engine-work/img_2116/' title='Added Bottom Lock'><img width="150" height="150" src="http://safefirefighter.com/files/2009/09/IMG_2116-150x150.jpg" class="attachment-thumbnail" alt="Added Bottom Lock" title="Added Bottom Lock" /></a>
</p>
<p>and challenging fire to be contained to the area of origin,</p>
<p>Sizing up commercial building for forcible entry problems gives companies a heads up when faced with a fire like that at Taylor Warehouse.  Crews were able to make decisions that allowed for quick access and a good stop.  Like anything in the fire service, we can’t be proficient at something we don’t practice.  Take out the saws, find something to cut (scrap, old locks, etc.) and know what you are capable of accomplishing prior to the emergency.</p>
]]></content:encoded>
			<wfw:commentRss>http://safefirefighter.com/2009/10/26/solid-truck-work-makes-for-easy-engine-work/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>Understaffed Truck Work: Forcible Entry</title>
		<link>http://safefirefighter.com/2009/03/03/understaffed-truck-work-forcible-entry/</link>
		<comments>http://safefirefighter.com/2009/03/03/understaffed-truck-work-forcible-entry/#comments</comments>
		<pubDate>Tue, 03 Mar 2009 17:18:09 +0000</pubDate>
		<dc:creator>safefirefighter</dc:creator>
				<category><![CDATA[Discussions]]></category>
		<category><![CDATA[Strategy and Tactics]]></category>
		<category><![CDATA[Truck Work]]></category>
		<category><![CDATA[crew]]></category>
		<category><![CDATA[entry]]></category>
		<category><![CDATA[forcible entry]]></category>
		<category><![CDATA[truck]]></category>

		<guid isPermaLink="false">http://safefirefighter.wordpress.com/?p=58</guid>
		<description><![CDATA[Most fire departments, if they are even lucky enough to staff a truck company, often struggle with how to maximize the tasks that [...]]]></description>
			<content:encoded><![CDATA[<div class="tweetmeme_button" style="float: right; margin-left: 10px;">
			<a href="http://api.tweetmeme.com/share?url=http%3A%2F%2Fsafefirefighter.com%2F2009%2F03%2F03%2Funderstaffed-truck-work-forcible-entry%2F"><br />
				<img src="http://api.tweetmeme.com/imagebutton.gif?url=http%3A%2F%2Fsafefirefighter.com%2F2009%2F03%2F03%2Funderstaffed-truck-work-forcible-entry%2F&amp;style=normal" height="61" width="50" /><br />
			</a>
		</div>
<p>Most fire departments, if they are even lucky enough to staff a truck company, often struggle with how to maximize the tasks that the truck can accomplish on the fireground.  Since times are tough and budgets are tougher, increasing staffing is unlikely. Below are some ideas to consider when trying to get the most from your truckies.</p>
<p>Our truck company will be staffed with three: an officer, driver and one firefighter.  We’re going to talk about fundamental truck functions like ladders, gaining entry, search and rescue and ventilation.  This article will focus on Forcible entry techniques.  We’re going to keep it simple and talk about conventional forcible entry and a touch of through the lock.</p>
<p>We can’t talk about forcible entry without talking tools, primarily the irons.  What separates any good crew from another is the mastering of the fundamentals.  What separates one truck company from the others is irons work.  The axe and Halligan are arguably the most versatile and reliable combination of tools available.  Since we can’t fight the fire unless we can get to it, irons work may also be the most important “x-factor” on the fireground.</p>
<p>A growing trend that I’ve seen is splitting up the irons, where the officer will carry the axe and the firefighter carries the halligan (or visa versa).  The problem with this  is that now you’ve taken an already limited crew and given it even fewer options.  The irons are ideal Because they can be married together and carried by ONE Firefighter.  This enables the officer to carry another tool such as a hook or sledge (or whatever) depending on the occupancy and FD SOG’s. Below are some tips for maximizing efficiency when forcing entry.  At the bottom are some videos showing great training ideas and efficient operations.</p>
<ul>
<li> You don’t need fancy props to practice your irons work.</li>
<li> Striking the tool from any position and in any conditions is often the first skill lost. To fix this, get a hold of tow landscape timbers, place them together vertically and ratchet strap them to any immovable object in the firehouse.  Use the seem in between the timbers as your jamb and strike away.</li>
<li> The other “issue” is that the irons are too cumbersome or heavy to carry.  The best remedy for this is to carry the irons more often.  Carry them together on all Fires, fire alarms, MVA’s, gas leaks, around the firehouse or whatever it takes to get used to it.</li>
<li> Learn about door construction, lock construction and their strengths and weaknesses.  Half the battle of forcible entry is knowing how and where to begin the operation.</li>
<li> Shock (a.k.a. sound) the doors by striking them with a tool at all 4 corners, at/around the lock(s).  This will not only indicate door construction, but help to locate additional locks and weaken any hardware that may be secured to the door and door frame.</li>
<li> Going through-the-lock after spinning the cylinder on commercial mortise locks may be the quickest way to gain entry without a K12.</li>
</ul>
<p>In the end, a successful forcible entry operation will depend on the crew’s ability to not only use the irons, but size-up, evaluate and adjust with the situation as well.</p>
<p>FTM-PTB and Be Safe</p>
]]></content:encoded>
			<wfw:commentRss>http://safefirefighter.com/2009/03/03/understaffed-truck-work-forcible-entry/feed/</wfw:commentRss>
		<slash:comments>2</slash:comments>
		</item>
	</channel>
</rss>
